Abstract
  • An integrated packaging system is developed for the multilayer laminate gas-phase microreactor die whosedesign and fabrication was described in Part 1 of this series. A commercial plastic socket used for integratedcircuit testing was adapted so the reactor chip could be easily installed while maintaining consistent alignmentwith all electrical contacts. A heated fluidics interface was developed that connects the nonmetallic feed andproduct gas ports on the microreactor chip to metal tubing. Thermal experiments and 3-D finite-element heattransfer simulations of the combined socket-fluidics assembly showed that the plastic reactor socket could besafely operated up to 250 °C. Other tests showed that the microreactor heaters were capable of achievingmembrane temperatures in excess of 600 °C. Step-response tests demonstrated that temperature changes ofca. 100 °C could be achieved in less than 10 ms. Testing of the electrical leads on the reactor chip verifiedthat the device resistance on a single reactor chip was uniform within a few percentage points. The packagedsystem developed here is used in Part 3 of this series to create a modular reactor board for incorporation intoan integrated process system.
article type
is part of this journal



Alternative Linked Data Documents: ODE     Content Formats:       RDF       ODATA       Microdata