Documentation scienceplus.abes.fr version Bêta

À propos de : Dark lumen magnetic resonance colonography: comparison with conventional colonoscopy for the detection of colorectal pathology        

AttributsValeurs
type
Is Part Of
Subject
Title
  • Dark lumen magnetic resonance colonography: comparison with conventional colonoscopy for the detection of colorectal pathology
has manifestation of work
related by
Abstract
  • Background: The purpose of this study was to assess the feasibility and usefulness of a new magnetic resonance (MR) colonography technique for the detection of colorectal pathology in comparison with conventional colonoscopy as the standard of reference. Patients and methods: A total of 122 subjects with suspected colorectal disease underwent “dark lumen” MR colonography. A contrast enhanced T1w three dimensional VIBE sequence was collected after rectal administration of water. The presence of colorectal masses and inflammatory lesions were documented. Results were compared with those of a subsequently performed colonoscopy. Results: MR colonography was found to be accurate regarding detection of clinically relevant colonic lesions exceeding 5 mm in size, with sensitivity and specificity values of 93%/100%. Conclusion: Dark lumen MR colonography can be considered as a promising alternative method for the detection of colorectal disease. In addition, it allows assessment of extraluminal organs.
article type
is part of this journal
PubMed ID
  • 14633953



Alternative Linked Data Documents: ODE     Content Formats:       RDF       ODATA       Microdata