Abstract
| - Objective. To evaluate the accuracy of urine protein-to-creatinine (P/C) ratio in an untimed urine specimen as compared with 24 h total protein excretion for measurement of proteinuria in patients with lupus nephritis. Methods. Proteinuria in patients with lupus nephritis was assessed by 24 h total protein excretion and spot urine P/C ratio. Correlation and limits of agreement between the two methods were evaluated. The discriminant cutoff values for spot urine P/C ratio in predicting 24 h protein ‘threshold’ excretion of ≥0.3, ≥0.5, ≥1.0 and ≥3.5 g/day were determined using receiver operating characteristic curves. Results. A total of 165 samples were available for assessment with 21.8% excluded due to inadequate collection. A strong correlation (r = 0.91, P< 0.0001) was found between spot urine P/C ratio and 24 h urine protein excretion. Bland-Altman plot showed the two tests had acceptable limits of agreement in low level of protein excretion (−0.86 to +0.92 g/day when protein excretion was <2.0 g/day). The limits became wider as the protein excretion increased. The spot urine P/C ratios of 0.45 (sensitivity 0.92; specificity 0.88), 0.7 (0.92; 0.89) and 1.84 (1.0; 0.86) mg/mg reliably predicted 24 h urine total protein equivalent ‘thresholds’ at ≥0.5, 1.0 and 3.5 g/day. Conclusion. This study supports the recommendation of using spot urine P/C ratio in screening and monitoring proteinuria in patients with lupus nephritis. However, in assessing the exact amount of proteinuria, the urine P/C ratio may have unacceptably wide limits of agreement in high protein excretion range.
|