Documentation scienceplus.abes.fr version Bêta

À propos de : Intra-aortic balloon pumping: effects on left ventricular diastolic function        

AttributsValeurs
type
Is Part Of
Subject
Title
  • Intra-aortic balloon pumping: effects on left ventricular diastolic function
has manifestation of work
related by
Author
Abstract
  • Objective: The intra-aortic balloon pump is the most widely used form of temporary cardiac assist and often utilised in patients before and after cardiac surgery. Several effects of balloon counter-pulsation have been reported previously, but its effect on left ventricular diastolic function has not been thoroughly investigated. The aim of this study is to examine the effect of the intra-aortic balloon pump on left ventricular wall motion and transmitral flow. Methods: We studied 20 patients in the intensive care unit, less than 36 h following cardiac surgery. We recorded left anterior descending coronary artery and transmitral E-wave flow velocities using transesophageal echocardiography pulsed Doppler. We also recorded left ventricular long axis free-wall movement using M-mode. The intra-aortic balloon pump was set to full augmentation and recordings were made at pumping cycles 1:1, 1:2, 1:3, and when the pump was on stand-by, leaving a minimum of 5 min between the pumping modes to allow the return to control conditions. In order to eliminate time effects, the sequence of recording was varied between patients using a 4 by 4 Latin-square. Results: The peak diastolic left anterior descending coronary artery and transmitral E-wave flow velocities, and left ventricular free-wall early diastolic lengthening velocity increased significantly with intra-aortic balloon pumping cycles 1:1, 1:2 and 1:3 compared to their value with the pump on stand-by, all P<0.001. The increase in peak transmitral E-wave flow velocity correlated with the increase in peak left anterior descending coronary artery diastolic flow velocity (r=0.74, P=0.02), and with the increase in left ventricular free-wall early diastolic lengthening velocity (r=0.80, P<0.001). Conclusion: Using the intra-aortic balloon pump post-cardiac surgery significantly increases peak diastolic left anterior descending coronary artery flow velocities and left ventricular free-wall early diastolic lengthening velocity, whose increase explains the increase in peak transmitral E-wave velocity. Although coronary flow is epicardial and mitral flow is intracardial, their close relationship suggests an improvement in left ventricular diastolic function with intra-aortic balloon pump.
article type
is part of this journal



Alternative Linked Data Documents: ODE     Content Formats:       RDF       ODATA       Microdata